EBW1 Universal Air Circuit Breaker (ACB)

    EBW1 Universal Air Circuit Breaker (ACB)

    The EBW1 Universal Circuit Breaker is an intelligent air circuit breaker (ACB) designed for AC 50Hz networks with rated voltages of 400V and 690V, and rated currents from 630A up to 6300A.It is widely used in low-voltage power distribution systems to ensure safe and efficient energy distribution, as well as to protect circuits and equipment from overload, short circuit, undervoltage, and single-phase grounding faults.Equipped with an intelligent electronic trip unit, the EBW1 ACB provides accurate and selective protection, preventing unnecessary power interruptions and enha...
  • ibahagi:
  • Makipag-ugnayan sa amin Online na Pagtatanong
  • Whatsapp:8613736779975

The EBW1 Universal Circuit Breaker is an intelligent Air circuit breaker (ACB) designed for AC 50Hz networks with rated voltages of 400V and 690V, and rated currents from 630A up to 6300A.
It is widely used in low-voltage power distribution systems to ensure safe and efficient energy distribution, as well as to protect circuits and equipment from overload, short circuit, undervoltage, and single-phase grounding faults.


Equipped with an intelligent electronic trip unit, the EBW1 ACB provides accurate and selective protection, preventing unnecessary power interruptions and enhancing the reliability of power supply systems.
The main components adopt advanced intelligent release technology, ensuring stable performance under complex working environments.


The EBW1 series fully complies with IEC 60947-1 and IEC 60947-2 standards, making it suitable for use in industrial, commercial, and infrastructure applications where reliability and precision protection are essential.


Operating Conditions

Ambient temperature: -5°C to +40°C (average within 24 hours ≤ +35°C)

Altitude: ≤ 2000 m

Pollution degree: Class 3

Humidity: ≤ 50% at +40°C; higher humidity levels are acceptable at lower temperatures (up to 90% at +20°C).
When condensation is likely to occur, appropriate anti-moisture measures should be applied.


Main technical parameter

Type
EBW1-2000EBW1-3200EBW1-6300
Pole
3P, 4P3P, 4P3P, 4P
Using category
BBB
Rated current InA630, 800, 1000 1250, 1600, 20002000, 2500, 30004000, 5000, 6300
Rated frequencyHz505050
Rated operation voltage UeV400, 690400, 690400, 690
Rated insulation voltage UiV800800800
Arcing distancemm000
Rated impulse withstanding voltage Uimp
V800080008000
Rated operation short circuit breaking capacity Ics (O-t-CO)400VkA5080100
690VkA405075
Rated limiting short circuit breaking capacity Icu (O-t-CO)400VkA80100120
690VkA506585
Rated short circuit closing capacity Icm400VkA176220264
690VkA105143187
Rated short time withstanding current Icw (O-t-CO, AC400V 0.4S)400VkA506585
Operation lifePer hourtimes202010
Electricaltimes1000500500
Mechanicaltimes1000050005000
Full breaking time
ms20~3020~3020~30
Full closing time
ms55~7055~7055~70
Power consumption3PW36012002000
4PW45017502300
Resistance of each poleFixed typeμΩ119-
Draw out typeμΩ201410
Dimensions (L×W×H)3P fixed typemm362×323×402422×323×402
3P draw out typemm375×461×452435×471×452
4P fixed typemm457×323×402537×323×402
4P draw out typemm470×461×452550×471×452
Approximate weight3P fixed typekg4155
3P draw out typekg7195245
4P fixed typekg51.565-
4P draw out typekg86115260


Overload protection data

Overload protectionEBW1-2000~6300
Adjust scope Ir1
(0.4-1)In (pole difference 2%)
1.05 Ir1h≥2h non-tripping
1.3 Ir1h≤1h tripping
Delay time tr1 when current is 2.0 Ins3.32, 5.32, 8.00, 13.3, 20, 26.6, 33.3, 45, 60, 93.3, 133, 200, 266, 333, 400, 433
Delay time tr1 when current is 3.0 Ins1.25, 2, 3.5, 7.5, 10, 12.5, 16.8, 22.5, 35, 50, 75, 100, 125, 150, 162
Accuracy%±10



Short circuit, short time delay 
Adjust scope Ir1 Ir2(0.4-15)In (pole difference 2%)
Delay time tr2ms100, 200, 300, 400
Accuracy%±10


Characteristic of intelligent controller

image.png Overload long time-delay anti-time limit protection
Short circuit short time-delay anti-time limit protection
Short circuit short time-delay timing protection
Short circuit instantaneous protection
Insulate earth fault protection


Electrical accessories

Under-voltage releaseRated working voltage Ue(V)AC400 AC230

1000A 3 pole ACB

Acting voltage (V)(0.35~0.7) Ue
Reliable close voltage (V)(0.85~1.1) Ue
Non close voltage (V)≤0.335Ue
Power loss12VA (EBW1-1000 5VA)

Shunt releaseRated control power voltage Us(V)AC400 AC230 DC220 DC110

1000A 3 pole ACB

Acting voltage (V)(0.7~1.1) Ue
Open time40VA 40W (EBW1-1000 5VA)
Power lossless than 30ms

Close electromagnetic ironRated control power voltage Us(V)AC400 AC230 DC220 DC110

1000A 3 pole ACB

Acting voltage (V)(0.85~1.1) Ue
Open time40VA 40W (EBW1-1000 5VA)
Power lossless than 70ms

Motor operating deviceRated control power voltage Us(V)AC400 AC230 DC220 DC110

1000A 3 pole ACB

Acting voltage (V)(0.85~1.1) Ue
Open time40VA 40W (EBW1-1000 5VA)
Power lossless than 5s

ONLINE NA MENSAHE

Mangyaring punan ang isang wastong email address
verification code Hindi maaaring walang laman

KAUGNAY NA MGA PRODUKTO

Contact Us

Phone: +8613736779975

E-mail: sales@vcbbreaker.com

Address: 66 Punan Road, Yueqing Economic Development Zone, Zhejiang, China

Copyright © 2025 Yangmei Electric Group Lahat ng mga karapatan ay nakalaan

Sitemap

Gumagamit ang website na ito ng cookies upang matiyak na makukuha mo ang pinakamahusay na karanasan sa aming website.

Tanggapin tanggihan